Elementor 页眉 #54

Veterinary Anesthesia Machine CV600

Model:      CV600

Buy the Veterinary Anesthesia Machine CV600 from UtrueMed. We have built this state-of-the-art device for effective anesthesia management for your animal patients. It can be used to treat animals weighing up to 200 kg and has manual and mechanical ventilation for safer operation.The CV600 comes with a 7″ screen with separate information, alarm, monitoring, and setting areas.It includes a high-precision mechanical flowmeter and a vaporizer with temperature, pressure, flow compensation, and self-lock functions. Whether in a veterinary clinic, research facility, or mobile practice, the Veterinary Anesthesia Machine CV600 sets the standard for excellence in veterinary anesthesia.

Additional information

Product Details:

Product Features
  •  7″ screen displays information area, alarm area, monitoring area, and setting area.
  •  High precision mechanical flowmeter, instantly know the fresh gas flow to animals.
  •  Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime.
  •  Real time pressure-time, flow-time oscillogram.
  •  Manual and mechanical ventilation for safer operation.
  •  External sensor design makes parameters setting more accurate. Wide use range for animals within 200KG.
  •  Anesthesia Gas Scavenging System (AGSS) are optional

 

Ventilation mode IPPV, A/C, SIMV, SIGH, MANUAL
Ventilator parameter range
Flowmeter O2 (0~5L/min)
Rapid oxygen supply 25L/min~75L/min
Tidal volume (Vt) 0, 20 mL ~ 1500 mL
Frequence  (Freq) 1/min~100/min
I:E 2:1 ~1:6
Pressure triggering sensitivity (Ptr) -20 cmH2O~0 cmH2O(Based on PEEP)
Flow trigger sensitivity (Ftr) 0.5 L/min ~ 30 L/min
SIGH 0(off)  1/100 ~ 5/100
Apnea ventilation OFF ,5 s ~ 60 s
Pressure Limit 20 cmH2O ~ 100 cmH2O
Monitoring parameter
Frequence (Freq) 0 /min ~ 100 /min
Tidal volume (Vt) 0 mL ~ 2000 mL
MV 0 L/min ~ 100 L/min
Alarm and protection
The AC power failure alarm Power failure or no connection
Low voltage alarm for back up battery <11.3±0.3V
No tidal volume ≤5mL within 6s
High oxygen concentration alarm 19%- 100%
Low oxygen concentration alarm 18%-99%
High airway  pressure alarm 20cmH2O- 100cmH2O
Low airway  pressure alarm 0cmH2O-20cmH2O
High minute volume alarm 1L/min-20L/min
Low minute volume alarm 0L/min- 10L/min
Continuous pressure alarm (PEEP+1.5kPa) over 16s
Suffocation warning 5s-60s no spontaneous ventilation
The maximum limited pressure <12.5 kPa
Fan error Show on screen
Oxygen deficit Show on screen
Working condition
Gas source O2
Pressure 280kPa-600kPa
Voltage 100-240V
Power frequency 50/60Hz
Oscillogram P-T (pressure – time), F-T (flow – time)
Wooden case size
Main component packing size L 680*W 840*H 695mm
G.W. 60KG
N.W. 26KG
Accessary packing size L 650*W 690*H 520mm
G.W. 29KG
N.W. 11KG
Total CBM 0.633m³

Ask For A Quick Quote