Model: M7
Improve patient care and outcomes with Utruemed’s 7-Inch Patient Monitor M7. The 7” Color TFT display with touchscreen features makes it convenient for all settings. Our state-of-the-art patient monitor offers a comprehensive range of features. It is portable and convenient for bedside monitoring or ambulatory care, with more than four hours of operation on the battery. The unique human voice alarm makes it ideal for handling emergencies. The monitor ensures accurate and real-time monitoring of vital signs, allowing your team to monitor the patient’s condition and make informed decisions promptly.The monitor displays ECG,RESP,TEMP,NIBP,SPO2, and PR in standard configuration.
Product Features:
standard: ECG,RESP,TEMP,NIBP,SPO2,PR
optional: Touch Screen, EtCO2,CMS
Technical Specification | |
ECG | |
Lead model | 5 Leads (I, II, III, AVR, AVL,AVF, V) |
Gain: | 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV |
Heart Rate | |
Measure range | Adult:15-300 bpm, Neonatal/Pediatric: 15-350 bpm |
Accuracy | 1% |
Resolution | 1 bpm |
Sensitivity | > 200 μVP-P |
Differential Input Impedance | > 5 MΩ |
CMRR | Diagnostic Mode>90 dB, Monitor Mode>110 dB, Surgery, Mode>110 dB |
Offset Potential | ± 300mV |
Leakage Current | < 10 μA |
Pace Pulse Detect | Range:± 2~± 700mV, Width:0.1~2ms, Rise Time:10-100 μs |
Pace Pulse Rejection | Range:± 2~± 700mV, Width:0.1~2ms, Rise Time:10-100 μs |
Baseline Recovery | < 3 s After defibrillation. |
ECG Signal Range | ± 5 mV (Vp-p) |
Bandwidth | Surgery: 1-20 Hz, Monitor: 0.5-40 Hz, Diagnostic: 0.05-130 Hz |
Calibration Signal: | 1 mV p-p, ± 5% accuracy |
ST measurement: | Range:-2.0-+2.0 mV |
Accuracy | -0.8mV-+0.8mV,± 0.02mVor± 10%, which is greater;Other Range: unspecified |
Arrhythmia | 13 Types: ASYSTOLE, VFIB/VTAC, COUTPLET, BIGMINY,TRIGEMINY, R ON T, VT >2, BRADY, MISSED BEATS, PNP, PNC |
RESP | |
Method | Impedance between RA-LL or RA-LA |
Differential Input Impedance | >2.5 ΜΩ |
Respiration Impedance Range | 0.3-3Ω |
Base Impedance Range | 200 Ω-2000Ω |
Bandwidth | 0.3-2 Hz |
Gain | x0.25, x0.500, x1, x2, x4 |
Respiration Rate | |
Measurement Range | Adult:0 ~120 BrPM,Neonatal / Pediatric: 0~150 BrPM |
Resolution | 1 BrPM |
Accuracy | 0-6 BrPM: unspecified, 7-150 BrPM: ± 2 BrPM or ± 2% use the greater. |
Inspiriting current | < 300 μA RMS max |
Apnea Alarm | 10 -40 s |
NIBP | |
Method | Oscillometry |
Measure Mode | Manual, Auto, STAT |
Measure Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 min |
Measure Period in STAT Mode | 5 min |
Pulse Rate Range | 40 ~240 bpm |
Measure and Alarm Range | |
Adult Mode | SYS:40~280 mmHg, DIA:10~220 mmHg, MEAN:20~240 mmHg |
Pediatric Mode | SYS:40~220 mmHg, DIA:10~160 mmHg, MEAN:20~170 mmHg |
Neonatal Mode | SYS:35~135 mmHg, DIA:10~100 mmHg, MEAN:20 ~110 mmHg |
Static pressure accuracy | ± 3mmHg |
Resolution | 1mmHg |
Accuracy | Maximum Mean Error: ± 5mmHg, Maximum Standard Deviation: 8mmHg |
Overpressure Protection | Adult:300 mmHg, Pediatric:240 mmHg, Neonatal:150 mmHg |
SpO2 | |
Measurement Range | 0~100% |
Resolution | 1% |
Accuracy | 70% ~100% ± 2 %, 0%~69%: unspecified |
Pulse Rate Measure and Alarm Range | 20-250bpm |
Resolution | 1bpm |
Accuracy | ± 3bpm |
TEMP | |
Channel | 2 |
Measure and Alarm Range | 0~50 ℃ |
Resolution | 0.1℃ |
Accuracy | (no sensor): ± 0.1℃(25℃ – 45℃), ± 0.2℃(other);
(include sensor): ±0.2℃(32℃ – 42℃) ,± 0.3℃ (other) |