Utruemed introduces the latest Handheld Vital Signs Monitor YC-V4. It empowers healthcare professionals to monitor accurate vital signs. This state-of-the-art monitor offers comprehensive features in a user-friendly design for ease of use. The YC-V4 lets healthcare professionals precisely measure blood pressure, pulse rate, oxygen saturation, and temperature and improve patient outcomes. It has a 5″ LED touchscreen with 24 hours of battery life, which make it ideal for remote use. Reliable sensors and intelligent algorithms that support powerful data functions are the USPs of this handheld monitor. Its compact design makes YC-V4 ideal for use in different healthcare settings, including hospitals, clinics, and home care environments.
SpO2 | |
Measurement Accuracy | ±2%( 70% ~ 100% ),undefiend(0 ~ 69%) |
Measurement Range | 0–100% |
Alarm Range | Consistent with the display range, the alarm limit setting step length is 1% |
Pulse rate | |
Measurement Range | 20bpm ~ 254bpm |
Alarm Range | Consistent with the display range, the alarm limit is set to a step length of 1bpm |
Speed of refresh | 1 s |
Measurement Accuracy | ±3 bpm |
Pulse rate Mean | 8 s |
NIBP | |
Method of measurement | oscillation |
Parameter of measurement | Systolic, diastolic and mean arterial pressure |
Unit | mmHg, kPa |
Mode of operation | Manual, automatic, and continuous |
Systolic blood pressure range | Adult: 30 mmHg ~ 270mmHg
Child:30 mmHg ~ 230mmHg Neonate:30 mmHg ~ 135mmHg |
Diastolic blood pressure range | Adult:10 mmHg ~ 220mmHg
Child:10 mmHg ~ 165mmHg Neonate:30 mmHg ~ 100mmHg |
Mean pressure range | Adult:10 mmHg ~ 240mmHg
Child:10 mmHg ~ 175mmHg Neonate:30 mmHg ~ 110mmHg |
Measurement Accuracy | The maximum mean error is ±5 mmHg or ±4%, with the highest absolute value |
Measurement Range | Consistent with the display range, the alarm limit setting step length is 1mmHg |
Alarm delay time | <10s |
Cuff pressure range | 0 mmHg ~ 300 mmHg |
Cuff inflation rate | <50mmHg/s |
Static pressure measurement error | ±3mmHg (Overpressure protection is not achieved) |
Resolution of display | 1mmHg |
Repeatability | When measured at static continuous low pressure, the difference between repeated readings at each point within the scale range should not be greater than 4 mmHg |
Pressure sensor accuracy | The maximum error for pressure measurements in the cuff should be ±3 mmHg at any point in the range, regardless of boost or drop |
Pulse rate measurement | The measuring range is 40 bpm ~ 240 bpm, the measuring accuracy is ± 2% or ±2 bpm, the absolute value of both should be greater |