Handheld Vital Signs Monitor YC-V4

Model:        YC-V4

Utruemed introduces the latest Handheld Vital Signs Monitor YC-V4. It empowers healthcare professionals to monitor accurate vital signs. This state-of-the-art monitor offers comprehensive features in a user-friendly design for ease of use. The YC-V4 lets healthcare professionals precisely measure blood pressure, pulse rate, oxygen saturation, and temperature and improve patient outcomes. It has a 5″ LED touchscreen with 24 hours of battery life, which make it ideal for remote use. Reliable sensors and intelligent algorithms that support powerful data functions are the USPs of this handheld monitor. Its compact design makes YC-V4 ideal for use in different healthcare settings, including hospitals, clinics, and home care environments.

Additional information

Product Details:

Product Features
  •  5″ LED touch screen with resolution 480*854
  •  Available to measure SpO2, PR, blood pressure, body temperature
  •  Up to 24 working hours of battery
  •  Suitable for Neonatal,Child and Adult
  •  Display the PI indexto help medical staffjudge the reliability of the measurement
  •  Weak perfusion performance can reach 0.075%,with excellent anti-motion performance
  •  Powerful data function,support up to 28,000 pieces
  •  Standard: SPO2,NIBP,TEMP
  •  Optional: ETCO2,AG.

 

SpO2
Measurement Accuracy  ±2%( 70% ~ 100% ),undefiend(0 ~ 69%)
Measurement Range 0–100%
Alarm Range  Consistent with the display range, the alarm limit setting step length is 1%
Pulse rate
Measurement Range 20bpm ~ 254bpm
Alarm Range Consistent with the display range, the alarm limit is set to a step length of 1bpm
Speed of refresh 1 s
Measurement Accuracy ±3 bpm
Pulse rate Mean 8 s
NIBP
Method of measurement oscillation
Parameter of measurement Systolic, diastolic and mean arterial pressure
Unit mmHg, kPa
Mode of operation Manual, automatic, and continuous
Systolic blood pressure range Adult: 30 mmHg ~ 270mmHg

Child:30 mmHg ~ 230mmHg

Neonate:30 mmHg ~ 135mmHg

Diastolic blood pressure range Adult:10 mmHg ~ 220mmHg

Child:10 mmHg ~ 165mmHg

Neonate:30 mmHg ~ 100mmHg

Mean pressure range Adult:10 mmHg ~ 240mmHg

Child:10 mmHg ~ 175mmHg

Neonate:30 mmHg ~ 110mmHg

Measurement Accuracy The maximum mean error is ±5 mmHg or ±4%, with the highest absolute value
Measurement Range Consistent with the display range, the alarm limit setting step length is 1mmHg
Alarm delay time <10s
Cuff pressure range 0 mmHg ~ 300 mmHg
Cuff inflation rate <50mmHg/s
Static pressure measurement error ±3mmHg (Overpressure protection is not achieved)
Resolution of display 1mmHg
Repeatability When measured at static continuous low pressure, the difference between repeated readings at each point within the scale range should not be greater than 4 mmHg
Pressure sensor accuracy The maximum error for pressure measurements in the cuff should be ±3 mmHg at any point in the range, regardless of boost or drop
Pulse rate measurement The measuring range is 40 bpm ~ 240 bpm, the measuring accuracy is ± 2% or ±2 bpm, the absolute value of both should be greater